Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Configuring your SMDR output

Below you will find instructions on how Follow the instructions below to configure the SMDR output via a serial connection. These instructions are taken from the Alcatel OmniPCX Enterprise manual:

...

  1. Applications (Enter)
  2. Accounting (Enter)
  3. Review/Modify (Enter)
  4. All Instance (F1)
  5. Realtime ticket Output: Set this to ethernet. Note that if you don't have an appropriate license , you can may only select V24 (serial) here.
  6. Save changes and exit

...

  1. .

Below is an example of the data output from Alcatelan Alcatel OmniPCX Enterprise:

Screenshotmacro
Borderfalse
URLhttp://docs.call-logger.com:8090/download/attachments/4817041/alcatel_pbxs.png

...

...

Once NetPBX is configured and collecting data, log on in to TIM Plus as usual and apply the following settings:

  1. Click on the Directory tab.
  2. Click on Select the site you configured during the setup wizard and click Properties.
    Screenshotmacro
    Borderfalse
    URLhttp://docs.call-logger.com:8090/download/attachments/4817042/alcatel_omnipcx_enterprise_2.png
  3. Within the Site Properties window, select Alcatel OmniPCX Enterprise from the PBX model drop-down list.
  4. In the Connection method field, select No connection required from the drop-down list.
  5. Click on the Save button to apply the settings.

...