These instructions help you configure your Cisco UCME / UC500 to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.
Connection Type

Support Files


Required Tasks



Configure UCME to send SysLog events
Login to your Cisco UCME / UC500 via telnet, as shown below:
Now just enter the following SysLog commands:
Step | IOS commands | Description |
---|---|---|
1 | enable | Enter EXEC mode, enter password if requested. |
2 | conf t | Enter global configuration mode. |
3 | aaa new-model | Enable aaa accounting mode. |
aaa accounting connection h323 start-stop group SysLog | ||
gw-accounting syslog | ||
acct-template callhistory-detail | ||
4 | logging 192.168.1.1 | Specifies the IP address to send CDR data. Where '192.168.1.1' is the machine running TIM Plus. |
5 | end | Exit configuration mode. |
6 | wr | Save changes. |
Labels: