Tese instructions help you configure your NEC NEAX phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.
Connection Type

Support Files


Required Tasks




Configure your NEC NEAX
Enabling your SMDR output
Please speak with your phone maintainer to enable the SMDR output.
Configuring your Serial connection
Using the CAT (Customer Administration Terminal) in the system-programming mode, enter the following settings:
Field name | Details | ||
---|---|---|---|
CM40 | Output port & attributes defaults: 9600 baud, 8 data bits, no parity, 2 stop bits, DTR/RTS flow control. | ||
CM13+05 | Enable SMDR for incoming calls to required stations. | ||
CM13+06 | Enable SMDR for outgoing calls to required stations. | ||
CM35+14 | Enable SMDR for outgoing calls to required trunk routes. | ||
CM35+49 | Enable SMDR for incoming calls to required trunk routes. | ||
CM08 | If SMDR for incoming calls is enabled, specify whether it applies to all incoming calls or only to those with Account Codes. Include ANI/Caller ID for incoming calls.
|