hese instructions help you configure your Siemens HiCom/HiPath phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Connection Type
  TIM Enterprise listens for connections from this PBX.

Support Files
  Siemens HiCom-HiPath.TDT
  Siemens.TDS
Required Tasks
  Configure the SMDR output
  Configure TIM Enterprise

Configuring your SMDR output

By default, the SMDR output of a Siemens HiCom/HiPath phone system is not enabled. Contact your system maintainer for information about how to configure the SMDR output for incoming, outgoing and internal calls.

Configuring TIM Enterprise

Follow the steps below to configure TIM Enterprise to listen for SMDR data from your Siemens HiCom/HiPath:

  1. Click on the Directory tab.
  2. Choose the PBX object you want to configure and click  Properties.
  3. A new window will open. In the General tab, select Siemens HiCom-HiPath from the Data format list and tick the Keep a local backup of data box, as shown below:

  4. In the Connection tab, select Listen for connections from PBX from the Connection method list.
  5. Leave the Host field blank.
  6. In the Port field, enter 9000.
  7. Click on the Save button to apply the settings.

 

 